The ship water cooler is used in the driver's cab, centralized control room, power distribution room, kitchen and other places. The cabinet is mainly composed of an air handling part, a compression condensing unit part and a control box. Before leaving the factory, the whole machine has been debugged, and the customer can put it into operation after connecting the cables and water pipes.
l Fully enclosed compressor, quiet, high efficiency and low energy consumption.
l Air flow. 170 ~6460 m3/h
l Heating capacity. 3kW~ 24kW
l Cooling capacity: 1kW - 35kW
l Compressor, scroll or piston
l Cooling method; water cooled or air cooled
l Water cooled condenser, high efficient anti corrosive
Condensing lube: Cu、B10、B30
l Air cooled condenser, copper tube copper fin, inner high efficient tube
l Protection: high pressure, low pressure, low water
Pressure(water flow), lack phase, over voltage, under voltage,
overload and el heating overheat
l Heating method: hot water, steam, el heating and hot pump
l Control:Relay control or DDC control.
l Power supply: 3-380V/50Hz , 3-440V/60Hz
l High-efficiency unit, low vibration, shell and tube heat exchanger with anti-corrosion function.
l Direct-connected or belt-driven fan motor assembly reduces noise and vibration.
l Steel frame structure with plastic coating on the outside.
l The cooling and heating temperature can be set through the panel, and the temperature is automatically controlled. The remote control switch can be used as an optional device.
l A variety of working fluids are available, such as R22, R407C, R404A, R134a, R410A, R407F, R407H, R448A, R449A, R513A, R32, R454C, etc.
l The pressure test, vacuum test, and aging test have been completed before leaving the factory.
l Suitable for long-term operation in marine environment.
SYPAC | 22 | -- | R | 2 | F | 6 |
1 | 2 | 3 | 4 | 5 | 6 | 7 |
Serial number | Code meaning | |||||
1 | Equipment name | PAC--Cabinet type air conditioner | ||||
2 | Refrigerant code | 04A—R404A; 07C—R407C; 34a—R134a; 22-R22 etc. | ||||
4 | Function code | R—full return air, air out of the static pressure box; G—new air, air out of the duct | ||||
5 | Cooling code | Nominal cooling capacity(kw) | ||||
6 | Cooling water code | F—fresh water; S—sea water | ||||
7 | Electric system | 5—50Hz/380V/3Ph; 6—60Hz/440V/3Ph; | ||||
model | Air volume | Fan power consumption | Cooling capacity | Press power consumption | Water flow rate | Water pressure drop | weight | Dimensions |
m3/h | kw | kw | kw | m3/h | kPa | kg | mm | |
SYPAC22-R1 | 170 | 0.2 | 1 | 0.3 | 0.2 | <30 | 130 | 600x450x1600 |
SYPAC22-R2 | 340 | 0.3 | 2 | 0.6 | 0.4 | <30 | 140 | (Width x depth x height) |
SYPAC22-R3 | 510 | 0.3 | 3 | 0.9 | 0.6 | <30 | 150 | |
SYPAC22-R4 | 680 | 0.4 | 4 | 1.2 | 0.8 | <30 | 160 | |
SYPAC22-R5 | 850 | 0.4 | 5 | 1.5 | 1.0 | <30 | 170 | |
SYPAC22-R6 | 1020 | 0.5 | 6 | 1.8 | 1.2 | <30 | 180 | |
SYPAC22-R7 | 1190 | 0.6 | 7 | 2.1 | 1.4 | <30 | 200 | |
**50/60 Hz;Technical parameters are based on refrigerant R22; other refrigerants are available on demand. Fresh water cooling (36°C inlet water)/Sea water cooling (32°C inlet water) | ||||||||