成人午夜亚洲精品无码区,中文字幕人妻熟在线影院,亚洲精品久久久久久中文字幕,欧美牲交a欧美牲交aⅴ一,亚洲午夜精品a片一区二区小蝌蚪

Marine PAC

Detail

Back

The ship water cooler is used in the driver's cab, centralized control room, power distribution room, kitchen and other places. The cabinet is mainly composed of an air handling part, a compression condensing unit part and a control box. Before leaving the factory, the whole machine has been debugged, and the customer can put it into operation after connecting the cables and water pipes.

Fully enclosed compressor, quiet, high efficiency and low energy consumption.

Air flow. 170 ~6460 m3/h

Heating capacity. 3kW~ 24kW

Cooling capacity: 1kW - 35kW

Compressor, scroll or piston

Cooling method; water cooled or air cooled

Water cooled condenser, high efficient anti corrosive

Condensing lube: CuB10、B30

Air cooled condenser, copper tube copper fin, inner high efficient tube

Protection: high pressure, low pressure, low water

Pressure(water flow), lack phase, over voltage, under voltage,

overload and el heating overheat

Heating method: hot water, steam, el heating and hot pump

Control:Relay control or DDC control.

Power supply: 3-380V/50Hz , 3-440V/60Hz

High-efficiency unit, low vibration, shell and tube heat exchanger with anti-corrosion function.

Direct-connected or belt-driven fan motor assembly reduces noise and vibration.

Steel frame structure with plastic coating on the outside.

The cooling and heating temperature can be set through the panel, and the temperature is automatically controlled. The remote control switch can be used as an optional device.

A variety of working fluids are available, such as R22, R407C, R404A, R134a, R410A, R407F, R407H, R448A, R449A, R513A, R32, R454C, etc.

The pressure test, vacuum test, and aging test have been completed before leaving the factory.

Suitable for long-term operation in marine environment.

SYPAC

22

--

R

2

F

6

1

2

3

4

5

6

7

Serial number

Code meaning

1

Equipment name

PAC--Cabinet type air conditioner

2

Refrigerant code

04A—R404A; 07C—R407C; 34a—R134a; 22-R22 etc.

4

Function code

R—full return air, air out of the static pressure box; G—new air, air out of the duct

5

Cooling code

Nominal cooling capacity(kw

6

Cooling water code

F—fresh water; S—sea water

7

Electric system

5—50Hz/380V/3Ph; 6—60Hz/440V/3Ph;

 

model

Air volume

Fan power consumption

Cooling capacity

Press power consumption

Water flow rate

Water pressure drop

weight

Dimensions


m3/h

kw

kw

kw

m3/h

kPa

kg

mm

SYPAC22-R1

170

0.2

1

0.3

0.2

<30

130

600x450x1600

SYPAC22-R2

340

0.3

2

0.6

0.4

<30

140

(Width x depth x height)

SYPAC22-R3

510

0.3

3

0.9

0.6

<30

150


SYPAC22-R4

680

0.4

4

1.2

0.8

<30

160


SYPAC22-R5

850

0.4

5

1.5

1.0

<30

170


SYPAC22-R6

1020

0.5

6

1.8

1.2

<30

180


SYPAC22-R7

1190

0.6

7

2.1

1.4

<30

200


**50/60 HzTechnical parameters are based on refrigerant R22; other refrigerants are available on demand. Fresh water cooling (36°C inlet water)/Sea water cooling (32°C inlet water)