Air source/water source heat pump air conditioners for ships are used in the driver's cab, control room, power distribution room, kitchen and other places.
The cabinet is mainly composed of an air handling part, a compression condensing unit part and a control box. Before leaving the factory, the whole machine has been debugged, and the customer can put it into operation after connecting the cable and refrigerant pipeline.
? Fully enclosed compressor, quiet, high efficiency and low energy consumption.
? High-efficiency unit, low vibration, shell and tube heat exchanger with anti-corrosion function.
? Direct-connected or belt-driven fan motor assembly reduces noise and vibration.
? Steel frame structure, the inner surface of the machine is sprayed with plastic coating, and the outer machine is made of stainless steel.
? The cooling and heating temperature can be set through the panel, and the temperature is automatically controlled. The remote control switch can be used as an optional device.
? A variety of working fluids are available, such as R22, R407C, R404A, R134a, R410A, R407F, R407H, R448A, R449A, R513A, R32, R454C, etc.
? The pressure test, vacuum test, and aging test have been completed before leaving the factory.
? Suitable for long-term operation in marine environment.
Model representation method:
SYHPU | 22 | -- | R | 2 | A | 6 |
1 | 2 | 3 | 4 | 5 | 6 | 7 |
Serial number | Code meaning | |||||
1 | Equipment name | HPU—Heat pump air conditioner | ||||
2 | Refrigerant code | 04A—R404A; 07C—R407C; 34a—R134a; 22-R22 etc. | ||||
4 | Function code | R—full return air, air out of the static pressure box; G—new air, air out of the duct | ||||
5 | Cooling code | Nominal cooling capacity(kw) | ||||
6 | Hot source code | A—Air source W—Water source | ||||
7 | Electric system | 5—50Hz/380V/3Ph; 6—60Hz/440V/3Ph; | ||||
Technical Data Sheet:
model | Air volume | Fan power consumption | Cooling capacity | Heating capacity | Press power consumption | weight | Dimensions | ||||
Internal machine | Outside machine | waterplane | Internal machine | Outside machine | waterplane | ||||||
m3/h | kw | kw | kw | kw | kg | kg | kg | mm | mm | mm | |
SYPAC22-R1 | 170 | 0.2 | 1 | 1 | 0.3 | 80 | 80 | 80 | 600 X450 x1600 (Width x depth x height) | 1000 X500 x800 (Width x depth x height) | 1300 X650 x1350 (Width x depth x height) |
SYPAC22-R2 | 340 | 0.3 | 2 | 2 | 0.6 | 90 | 100 | 100 | |||
SYPAC22-R3 | 510 | 0.3 | 3 | 3 | 0.9 | 100 | 120 | 120 | |||
SYPAC22-R4 | 680 | 0.4 | 4 | 4 | 1.2 | 120 | 150 | 150 | |||
SYPAC22-R5 | 850 | 0.4 | 5 | 5 | 1.5 | 140 | 150 | 150 | |||
SYPAC22-R6 | 1020 | 0.5 | 6 | 6 | 1.8 | 160 | 150 | 150 | |||
SYPAC22-R7 | 1190 | 0.6 | 7 | 7 | 2.1 | 180 | 150 | 150 | |||
**50/60 Hz;Technical parameters are based on refrigerant R22; other refrigerants are available on demand. | |||||||||||