Marine AHU

Detail

Back

The air-conditioning box for ships is an important device for processing the temperature and humidity of the air in the cabin. (MAUK air-conditioning box adopts a zigzag frame for light and middle-weight work environment, HAUK air-conditioning box adopts a square tube frame for heavy-weight work environment)

The conventional air-conditioning box has the following functional sections to form an air mixing section, a filter section, a heating section, a humidification section, a cooling section, a water retaining section, a fan section, a runner section, purification and disinfection and other functional sections as required.?Features: low noise, reliable run and complete protections

Air flow: 720 ~ 840000 m3/h

External static pressure: 500-1700Pa

Heating capacity. 5kW ~ 1700kW

Cooling capacity. 5kW ~ 1700kW

Protection: power supply protection, overheat overload,

antifreeze and filter mesh clog.

Low noise design: low noise fan with vibration mounted,

optional perforated sheet design

Control: Relay control or PLC control

Optional control: auto regulate supply water flow as per the

return air/supply air, the ratio of fresh air/return air can be auto

controlled

Power supply:3-380V/50Hz , 3-440V/60Hz?Upon requested, special Ex air handling unit can be made with

normal class ExdⅡBT4

Panel frame: anti-corrosion galvanized steel, plastic-sprayed steel, stainless steel, etc. can be selected.

50mm thick insulated rock wool double-layer metal panel.

Direct-connected or belt-driven fan motor assembly reduces noise and vibration.

Equipped with detachable access door.

A variety of working fluids are available, such as R22, R407C, R404A, R134a, R410A, R407F, R407H, R448A, R449A, R513A, R32, R454C, refrigerant water.

Heating medium: steam, hot water, hot oil, electric heating.

Humidification medium: steam, fresh water, compressed air + fresh water

The pressure test and vacuum test have been completed before leaving the factory. 

Suitable for long-term operation in marine environment.

MAUK

10

09





1

2

3





Serial number

Code meaning

1

Device name code

MAUK—Light and middleweight air conditioning box; HAUK—Heavyweight air conditioning box

2

Box width code

10—1027mm width; 14—1417mm width19—1947mm width

25—2540mm width; 31—3125 width

Note: Custom size on demand



3

Cabinet height code

05—517mm height06—667mm height;09—917mm height11—1117mm height;13—1317mm height; 16—1617mm height;19—1947mm height;25—2540mm height

Note: Custom size on demand


                 AHU model
     Item          MAHK/HAHK

1005

1006

1009

1010

1406

1409

1413

1414

1909

1911

1913

1916

1919

2519

2525

3125

Air flow

Min

m3/s

0.20

0.30

0.47

0.53

0.48

0.69

1.13

1.26

1.01

1.34

1.63

2.11

2.59

3.60

4.81

6.20

m3/h

720

1080

1692

1908

1728

2484

4068

4536

3636

4824

5868

7596

9324

12960

17316

22320

Max

m3/s

0.92

1.39

2.16

2.46

2.01

2.93

4.75

5.31

4.01

5.35

6.50

8.41

10.32

13.88

18.51

23.39

m3/h

3312

5004

7776

8856

7236

10548

17100

19116

14436

19260

23400

30276

37152

49968

66636

84204

Cooling capacity

Min

KW

4

5

8

10

9

12

20

23

18

24

29

38

47

65

86

111

Max

KW

66

99

154

175

143

209

339

379

256

381

463

599

737

989

1319

1667

Heating capacity

Min

KW

5

7

12

13

12

17

28

31

25

33

40

52

64

88

118

152

Max

KW

68

102

159

181

148

216

350

391

296

394

479

620

761

1023

1364

1724

Humidifying
     Capacity

Max

kg/h

32

49

75

86

70

102

166

185

140

187

227

294

360

485

646

817

Nominal External
     Static pres.

Pa

500

1000

1700

1700

1700

1700

1700

1700

1700

1700

1700

1700

1700

1700

1700

1700

Centrifugal  Fan & Motor

Type

Belt drive or coupling connection as    option on request

Max Fan
     size

180

280

355

355

315

355

450

450

400

500

560

630

710

800

900

1000

Max Motor
     Power KW

3.5

4.7

8.7

17.5

8.7

17.5

25.6

25.6

21.5

34.9

34.9

43.1

64

87

104

128

Cooling medium

R404A (R407C /R134A/R417A/other second    refrigerant)

Heating medium

Steam, hot water, electric, or thermal    oil

Humidifying medium

Steam, fresh water + compressed air, or    fresh water

Power Supply

3Ph, 440V, 60Hz, or 380V 50Hz,or 690V

?  Normal design condition    basing on ISO7547:
     Summer: Inside temperature 27℃,    relative humidity 50%; outside temperature 35℃, relative humidity 70%;
     Winter:     Inside temperature 22℃, relative humidity 50%; outside temperature -20℃;
     Fresh air rate: 0~100%;
     Room supply temperature 17℃ for    summer, and 40℃ for winter.
     ?  Other design is available    on request (refrigerant, static pressure etc.)
     ?  Min. air flow is basing on    air face velocity 1.0m/s at coil.
     ?  Max. air flow is basing on    air face velocity 3.5m/s at coil or per AHRI410 on rquest.
     ?  Min. capacity (cooling    & heating) is basing on both min. air flow and 0% fresh air rate.
     ?  Max. capacity (cooling    & heating) is basing on both max. air flow and 100% fresh air rate.
     ?  Explosion-proof unit is    available on request (during enquiry pls provide ex requirement such as Zone    X hazadous area, Gas Group, Temperature Class)