Compression condensing unit for ships is composed of compressor, oil separator, shell and tube heat exchanger, liquid supply valve, filter drier, sight glass, shut-off valve and junction box.
By connecting the refrigerant pipeline between the air conditioning box and the compression condensing unit, and the cable between the electric control box and the junction box, the unit can be put into operation after the cooling water pipeline is connected.
l Available compressor packages: coupling/belt open type, semi-enclosed type, fully enclosed.
l Features: reliable run, anti corrosive and complete protections
l Cooling capacity : 50kW-320kW
l Refrigerant : R22, R407C,R404A,R134a,R410A,R407F,R407H,R448A,R449A,R513A,R32,R454C等。
l Compressor: piston or screw type/open or semi-hermetic
l No of compressor : single or multi
l Capacity control : multistage selectable
l Cooling method : water cooled or air cooled
l Water cooled condenser : high efficient anti corrosive
Condensing tube: Cu 、B10 、B30
l Air cooled condenser : copper tube copper fin, inner high efficient tube
l Protection: high pressure, low pressure, oil pressure(oil level),
low water pressure(water flow), lack phase, over voltage, under
voltage, overheat and overload
l Control: button control or PLC control
l Power supply : 3-380V/50Hz , 3-440V/60Hz?Upon requested, special Ex condensing unit can be made with
normal class ExdⅡBT4
l Washable shell and tube shell and tube heat exchanger, fresh water cooling type uses brass heat exchange tubes; sea water cooling type uses copper-nickel heat exchange tubes.
l The pressure test and vacuum test have been completed before leaving the factory.
l Suitable for long-term operation in marine environment.
SYMCU | 22 | -- | P | 20 | F | 6 | |
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
Serial number | Code meaning | ||||||
1 | Equipment name | MCU—Compression condensing unit for ships | |||||
2 | Refrigerant code | 04A—R404A; 07C—R407C; 34a—R134a; 22-R22;10A--R410A; 07F--R407F; 07H--R407H;48A--R448A; 49A--R449A; 13A--R513A; 32--R32; 54C--R454C etc. | |||||
4 | Compressor type | P: Piston S: Screw type R: Scroll | |||||
5 | Cooling code | Nominal cooling capacity, unit: cold | |||||
6 | Cooling water type | F—freshwater S—seawater | |||||
7 | Electric system | 5—50Hz/380V/3Ph; 6—60Hz/440V/3Ph; | |||||
8 | Compressor drive mode | "_"The default direct connection; V—belt drive | |||||
model | Cooling capacity** | input power** | Cooling water flow** | Cooling water pressure drop** | weight** | Dimensions** | |
(Length x width x height) | |||||||
kw | kw | kw | kw | kg | mm | ||
SYMCU-22-*15,20 | 50~75 | 15~20 | 11~18 | 13~25 | 400 | 1400X700x1350 | |
SYMCU-22-*30 | 80~105 | 25~30 | 17~22 | 23~25 | 500 | 1600X700x1450 | |
SYMCU-22-*40 | 105~150 | 30~45 | 22~32 | 25~35 | 520 | 1600X700x1500 | |
SYMCU-22-*50 | 150~180 | 50~55 | 35~40 | 30~40 | 650 | 1800X750x1550 | |
SYMCU-22-*60 | 180~210 | 55~60 | 40~48 | 42~44 | 810 | 2200X1000x2050 | |
SYMCU-22-*70 | 210~255 | 60~70 | 50~60 | 35~45 | 1020 | 2200X1000x2050 | |
SYMCU-22-*80 | 260~320 | 75~90 | 60~70 | 40~50 | 1040 | 2200X1000x2050 | |
**50/60 Hz; technical parameters are based on refrigerant R22; other refrigerants are available on demand. Fresh water inlet temperature: 36°C; seawater inlet temperature: 32°C. Evaporation temperature superheat is based on "ANSI/AHRI STANDARD 540" | |||||||