Marine Chilled Water Unit

Detail

Back

Ship cooling water chillers can provide chilled water for ship air conditioning systems, low-sulfur oil cooling systems and other special applications. The device is composed of a semi-hermetic piston compressor or a twin-screw semi-hermetic compressor, a water-cooled shell and tube heat exchanger, a dry expansion evaporator, an expansion valve, a filter, a sight glass, a shut-off valve, a control box, etc. After connecting the power supply, cooling water system and chilled water system, the user can conveniently operate the unit.

The available compressor types include open type, semi-closed type, and fully closed type.

Feature: reliable run, anti corrosive and complete protections

Cooling capacity: 50kW ~ 2000kW

Refrigerant: R407C、R134a、R404A、R22、R410AR407F、R407H、R448A、R449A,R513A、R32R454C

Compressor: piston or screw type/open or semi-hermetic

No of compressor : single or multi

Capacity control: multistage selectable

Cooling method: water cooled or air cooled

Water cooled condenser; high efficient anti corrosive

Condensing tube: CuB10、B30

Air cooled condenser : copper tube copper fin, inner high efficient tube

Protection : high pressure, low pressure, oil pressure(oil level),

low water pressure(water flow), anti freeze, lack phase, over voltage, under voltage, overheat and overload

Control: button control or PLC control

Power supply: 3-380V/50Hz , 3-44OV/6OHz

Washable shell and tube shell and tube heat exchanger, fresh water cooling type uses brass heat exchange tubes; sea water cooling type uses copper-nickel heat exchange tubes.

The chilled water temperature can be set through the panel, and the temperature is automatically controlled.

The pressure test, vacuum test, and aging test have been completed before leaving the factory. 

Suitable for long-term operation in marine environment.


SYMCWU

22

--

20

F

6

_


1

2

3

4

5

6

7


Serial number

Code meaning

1

Equipment name

MCWU—Marine refrigerant water unit

2

Refrigerant code

04A—R404A; 07C—R407C; 34a—R134a; 22-R22 ; 10A--R410A07F--R407F; 07H--R407H;48A--R448A; 49A--R449A; 13A--R513A;32--R32; 54C--R454C etc.

4

Cooling code

Nominal cooling capacity, unit: coldton

5

Cooling water type

F—freshwater      S—seawater

6

Electric system

5—50Hz/380V/3Ph; 6—60Hz/440V/3Ph;

7

Refrigeration system configuration

"_"The default single system; T—double system







model

Cooling capacity**

input power**

Refrigerant water flow**

Refrigerant water pressure drop**

Cooling water flow**

Cooling water pressure drop**

weight**

Dimensions**


(Length x width x height)

kw

kw

m3/h

KPa

m3/h

KPa

kg

mm

SYMCU-22-15

50

15

9

30

9

30

1000

2500X900x1350

SYMCU-22-20

75

22

12

35

12

35

1100

2500X900x1350

SYMCU-22-30

100

30

18

28

18

28

1250

2950X1250x1300

SYMCU-22-70

250

75

45

40

45

40

1695

3000X1350x1480

SYMCU-22-140

500

150

90

40

90

40

2550

3600X1730x1740

SYMCU-22-200

750

220

120

35

120

35

3510

3600X1830x1840

SYMCU-22-280

1000

300

180

30

180

30

3800

3700X1900x1900

**50/60 Hz; technical parameters are based on refrigerant R22; other refrigerants are available on demand.


Fresh water inlet temperature: 36°C; seawater inlet temperature: 32°C. Evaporation temperature superheat is based on "ANSI/AHRI STANDARD 540"