Ship cooling water chillers can provide chilled water for ship air conditioning systems, low-sulfur oil cooling systems and other special applications. The device is composed of a semi-hermetic piston compressor or a twin-screw semi-hermetic compressor, a water-cooled shell and tube heat exchanger, a dry expansion evaporator, an expansion valve, a filter, a sight glass, a shut-off valve, a control box, etc. After connecting the power supply, cooling water system and chilled water system, the user can conveniently operate the unit.
l The available compressor types include open type, semi-closed type, and fully closed type.
l Feature: reliable run, anti corrosive and complete protections
l Cooling capacity: 50kW ~ 2000kW
l Refrigerant: R407C、R134a、R404A、R22、R410A、R407F、R407H、R448A、R449A,R513A、R32、R454C
l Compressor: piston or screw type/open or semi-hermetic
l No of compressor : single or multi
l Capacity control: multistage selectable
l Cooling method: water cooled or air cooled
l Water cooled condenser; high efficient anti corrosive
Condensing tube: Cu、B10、B30
l Air cooled condenser : copper tube copper fin, inner high efficient tube
l Protection : high pressure, low pressure, oil pressure(oil level),
low water pressure(water flow), anti freeze, lack phase, over voltage, under voltage, overheat and overload
l Control: button control or PLC control
l Power supply: 3-380V/50Hz , 3-44OV/6OHz
l Washable shell and tube shell and tube heat exchanger, fresh water cooling type uses brass heat exchange tubes; sea water cooling type uses copper-nickel heat exchange tubes.
l The chilled water temperature can be set through the panel, and the temperature is automatically controlled.
l The pressure test, vacuum test, and aging test have been completed before leaving the factory.
l Suitable for long-term operation in marine environment.
SYMCWU | 22 | -- | 20 | F | 6 | _ | |
1 | 2 | 3 | 4 | 5 | 6 | 7 | |
Serial number | Code meaning | ||||||
1 | Equipment name | MCWU—Marine refrigerant water unit | |||||
2 | Refrigerant code | 04A—R404A; 07C—R407C; 34a—R134a; 22-R22 ; 10A--R410A;07F--R407F; 07H--R407H;48A--R448A; 49A--R449A; 13A--R513A;32--R32; 54C--R454C etc. | |||||
4 | Cooling code | Nominal cooling capacity, unit: coldton | |||||
5 | Cooling water type | F—freshwater S—seawater | |||||
6 | Electric system | 5—50Hz/380V/3Ph; 6—60Hz/440V/3Ph; | |||||
7 | Refrigeration system configuration | "_"The default single system; T—double system | |||||
model | Cooling capacity** | input power** | Refrigerant water flow** | Refrigerant water pressure drop** | Cooling water flow** | Cooling water pressure drop** | weight** | Dimensions** | |
(Length x width x height) | |||||||||
kw | kw | m3/h | KPa | m3/h | KPa | kg | mm | ||
SYMCU-22-15 | 50 | 15 | 9 | 30 | 9 | 30 | 1000 | 2500X900x1350 | |
SYMCU-22-20 | 75 | 22 | 12 | 35 | 12 | 35 | 1100 | 2500X900x1350 | |
SYMCU-22-30 | 100 | 30 | 18 | 28 | 18 | 28 | 1250 | 2950X1250x1300 | |
SYMCU-22-70 | 250 | 75 | 45 | 40 | 45 | 40 | 1695 | 3000X1350x1480 | |
SYMCU-22-140 | 500 | 150 | 90 | 40 | 90 | 40 | 2550 | 3600X1730x1740 | |
SYMCU-22-200 | 750 | 220 | 120 | 35 | 120 | 35 | 3510 | 3600X1830x1840 | |
SYMCU-22-280 | 1000 | 300 | 180 | 30 | 180 | 30 | 3800 | 3700X1900x1900 | |
**50/60 Hz; technical parameters are based on refrigerant R22; other refrigerants are available on demand. Fresh water inlet temperature: 36°C; seawater inlet temperature: 32°C. Evaporation temperature superheat is based on "ANSI/AHRI STANDARD 540" | |||||||||