SYMRD type ship-use rotary dehumidifier is an important device used to treat the air humidity in the service area of multi-purpose ships (such as grain ships, pulp ships, sugar ships, chemical tankers, etc.). Usually this type of dehumidifier consists of the following functional sections: regeneration air filter, regeneration heater, regeneration fan motor section; dehumidification runner, processing air filter, processing fan motor section;
l Equipment panel and frame: anti-corrosion material: aluminum-zinc plate or stainless steel.
l Optional panel insulation thickness of 25mm, 30mm, 50mm.
l High-efficiency fiber composite silica gel runner: reliable, durable and washable, high moisture absorption, good fire resistance: zero combustion index and zero smoke index.
l Regenerative heating medium: electric heating, steam heating, or hot oil heating.
l Suitable for long-term operation in marine environment.
l Features: reliable performance. easy operation, high auto degree, environment friendly
refrigerant, utilization of condensing heat, economic & save
l Product series: normal dehumidifier, duct dehumidifier,combination dehumidifier and fresh air dehumidifier and constant temp humidistat
l Applicable range: 5 – 35°C
l Application: shipbuilding, offshore engineering,medicine and aerospace, civil air defence,
purificationengineering, subway station, ammunition store, lab,telecommunication equipment room,
file room and food room etc
Dehumidifier model | 300E | 600E | 900E | 1500E | 3000E | 5000E | 8000E | 12000E | 20000E | 25000E | 30000E | |
Processing air flow | m3/h | 300 | 600 | 900 | 1500 | 3000 | 5000 | 8000 | 12000 | 20000 | 25000 | 30000 |
React air flow | m3/h | 100 | 200 | 300 | 500 | 1000 | 1667 | 2667 | 4000 | 6667 | 8333 | 10000 |
Rated | kg/h | 3 | 5 | 6 | 10 | 18 | 31 | 50 | 81 | 129 | 160 | 203 |
Processing fan-motor power | kW | 0.75 | 0.75 | 1.5 | 2.2 | 3.0 | 4.0 | 5.5 | 7.5 | 15 | 18.5 | 22 |
React fan-motor | kW | 0.04 | 0.06 | 0.18 | 0.37 | 1.1 | 1.5 | 2.2 | 3.0 | 7.5 | 11 | 15 |
React heating capacity | kW | 2.7 | 5.4 | 8.2 | 18 | 36 | 60 | 96 | 144 | 240 | 300 | 353 |
Std. rotor diameter | mm | 250 | 370 | 450 | 550 | 770 | 965 | 1220 | 1525 | 1940 | 2190 | 2450 |
Rotor reducer | kW | 0.09 | 0.09 | 0.09 | 012 | 0.18 | 0.25 | 0.25 | 0.37 | 0.37 | 0.37 | 0.37 |
Processing air inlet/outlet | mm | 120x120 | 160x160 | 250x160 | 320x200 | 500x320 | 800x320 | 800x500 | 1000x630 | 1250x800 | 1600x800 | 1600x1000 |
React air inlet | mm | 120x120 | 120x120 | 160x160 | 320x250 | 550x225 | 630x400 | 750x500 | 800x500 | 800x630 | 850x650 | 875x550 |
React air outlet | mm | Φ100 | Φ100 | Φ150 | 125x125 | 200x175 | 200x200 | 200x320 | 200x320 | 320x250 | 525x300 | 500x350 |
Referred overall dimension | L | 1200 | 1400 | 1400 | 1150 | 1350 | 1500 | 1620 | 1870 | 2270 | 2200 | 2200 |
W | 550 | 700 | 700 | 920 | 1150 | 1350 | 1540 | 1960 | 2150 | 2300 | 2600 | |
H | 650 | 800 | 800 | 1680 | 1950 | 2320 | 2660 | 3390 | 3530 | 3560 | 4360 | |
Weight | kg | 100 | 120 | 170 | 220 | 260 | 350 | 420 | 550 | 700 | 900 | 1200 |
?Normal design condition: | ||||||||||||